<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>H.V.A.C. Al &#187; safety maintenance</title>
	<atom:link href="http://hvac-al.com/tag/safety-maintenance/feed" rel="self" type="application/rss+xml" />
	<link>http://hvac-al.com</link>
	<description>Houston&#039;s A.C. and Heating Expert</description>
	<lastBuildDate>Thu, 20 Aug 2009 03:32:55 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.1</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Maintenance Check Ups</title>
		<link>http://hvac-al.com/maintenance-check-ups-17.htm</link>
		<comments>http://hvac-al.com/maintenance-check-ups-17.htm#comments</comments>
		<pubDate>Sat, 22 Mar 2008 04:07:18 +0000</pubDate>
		<dc:creator>jackie</dc:creator>
				<category><![CDATA[Tips]]></category>
		<category><![CDATA[Attic Cat insulation]]></category>
		<category><![CDATA[attic insulation]]></category>
		<category><![CDATA[attic ventilation]]></category>
		<category><![CDATA[condenser maintenance]]></category>
		<category><![CDATA[flex duct]]></category>
		<category><![CDATA[furnace maintenance]]></category>
		<category><![CDATA[heater maintennace]]></category>
		<category><![CDATA[maintenance]]></category>
		<category><![CDATA[metal ductwork]]></category>
		<category><![CDATA[R value insulation]]></category>
		<category><![CDATA[safety maintenance]]></category>

		<guid isPermaLink="false">http://hvac-al.com/maintenance-check-ups-17.htm</guid>
		<description><![CDATA[Ask for an inspection of your&#8230;
1.        DUCTWORK
2.        CONDENSING UNIT
3.        EVAPORATOR COIL
4.        HEATER/FURNACE
5.        SUPPLY REGISTER AND RETURN AIR GRILLS 
6.        ATTIC INSULATION &#38; VENTILATION
 
Also ask for a Mechanical inspection of your system, including but not limited to: 
ü        CHECK REFRIGERANT LEVELS TO MANUFACTURERS SPECIFICATIONS USING SUPERHEAT
 OR SUB-COOLING
ü        CHECK AMPERAGE DRAW PER UNIT DATA PLATE FOR COMPRESSOR
ü        CHECK [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt"><strong><span style="font-size: 10.5pt">Ask for an inspection of your&#8230;</span></strong></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"><span style="font-size: 8pt">1.<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">DUCTWORK</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"><span style="font-size: 8pt">2.<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CONDENSING UNIT</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"><span style="font-size: 8pt">3.<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8pt">EVAPORATOR COIL</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"><span style="font-size: 8.5pt">4.<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">HEATER/FURNACE</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"><span style="font-size: 8pt">5.<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">SUPPLY REGISTER AND RETURN AIR GRILLS</span><span style="font-size: 8pt"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"><span style="font-size: 8pt">6.        ATTIC INSULATION &amp; VENTILATION</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 0.5in; text-indent: -0.25in; tab-stops: list .5in"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt"><strong><span style="font-size: 10.5pt">Also ask for a </span></strong><strong><span style="font-size: 11pt">Mechanical inspection of your system, including but not limited to:</span> </strong></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt"><span style="font-size: 9pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK REFRIGERANT </span><span style="font-size: 8pt">LEVELS TO MANUFACTURERS SPECIFICATIONS USING SUPERHEAT</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt"><span style="font-size: 8pt"> OR SUB-COOLING</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK AMPERAGE DRAW PER UNIT DATA PLATE FOR COMPRESSOR</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK AMPERAGE DRAW PER UNIT DATA PLATE FOR CONDENSER FAN MOTOR</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK AMPERAGE DRAW PER UNIT DATA PLATE FOR INDOOR BLOWER MOTOR</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK AND CLEAR DRAIN LINES</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK ALL ELECTRICAL CONNECTIONS</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK AND FUNCTION ALL CONTROLS AND SAFETIES</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK CONDITION OF HEAT EXCHANGER</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK CONDITION OF EVAPORATOR COIL</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">CHECK CONDITION OF CONDENSING COIL (WATER WASH IF NECESSARY)</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">VISUALLY INSPECT ALL VISIBLE AND ACCESSIBLE SUPPLY DUCTWORK</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">ü<span style="font-family: 'Times New Roman';">        </span></span><span style="font-size: 8.5pt">VISUALLY INSPECT RETURN AIR DUCTWORK AND CHASE</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt -0.05pt"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt"><strong><span style="font-size: 10.5pt">Finally, </span></strong></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt"><span style="font-size: 8.5pt; font-family: Wingdings;">?<span style="font-family: 'Times New Roman';">          </span></span><span style="font-size: 8.5pt">CHECK SUPPLY DUCTWORK FOR AIR LEAKS </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">?<span style="font-family: 'Times New Roman';">          </span></span><span style="font-size: 8.5pt">CHECK TOTAL SYSTEM STATIC PRESSURE</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">?<span style="font-family: 'Times New Roman';">          </span></span><span style="font-size: 8.5pt">CHECK FOR LEAKAGE AROUND ALL ACCESSIBLE SUPPLY REGISTERS</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">?<span style="font-family: 'Times New Roman';">          </span></span><span style="font-size: 8.5pt">DETERMINE SYSTEMS FUNCTIONING AIR FLOW CAPACITY </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">?<span style="font-family: 'Times New Roman';">          </span></span><span style="font-size: 8.5pt">DETERMINE SYSTEMS FUNCTIONING BTU CAPACITY</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt; font-family: Wingdings;">?<span style="font-family: 'Times New Roman';">          </span></span><span style="font-size: 8.5pt">DETERMINE SYSTEMS FUNCTIONING EFFICIENCY RATING</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"><span style="font-size: 8.5pt"><strong>Get a written evaluation of your system. Get a written proposal of any suggested work to be done and always get a second opinion.</strong></span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt 17.95pt; text-indent: -0.25in"> </p>